All model Building Codes mandate that polyurethane spray foam be separated from the interior of the building by a 15 minute thermal barrier or other approved covering. DC315 has passed certified ULC S101, NFPA 286 and UL 1715 testing, at recognized 3rd party testing facilities, over a variety of open and closed cell spray polyurethane foams. It complies with all the requirements of 2006 IBC Section 803.2.1; 2009 IBC Section 803.1.2 and Section 2603.9; 2012 IBC Section 803.1.2 and Section 2603.10 & & 2015 IBC Section 803.2.1 and IBC Section 2603.9 under “Special Approvals for Thermal Barriers over Foam Plastics”. DC315 also meets the requirement as an Ignition Barrier per AC 377, Appendix X at an incredible spread rate of 400 sq. ft. per gallon.

DC 315 applied over Spray Polyurethane (SPF), is an Alternative Barrier System in "Section 2603.9 Special Approval" as a thermal barrier. To be approved as an Alternative Barrier System, DC 315 is applied over a manufacturer's SPF and tested to the criteria of an NFPA 286, UL 1715, UL 1040, or FM 4880 for duration of 15 minutes by an accredited fire testing facility. Products that pass an ignition barrier tested under AC 377 Appendix X are not appropriate alternative thermal barriers and cannot be used. Depending on your particular application, either ignition or thermal barriers are required by the International Building Code (IBC).

 

DC315 Tested Solutions for the Spray Polyurethane Foam

* DC 315 is AC456 compliant

* More full scale Thermal and Ignition Barrier tests than any other product in the world

* DC 315 - 3rd. party inspected for Quality Control: Warnock Hersey Intertek W/N 20947

* Tested useful life, fire resistant property is not compromised after 50 years

* Top coat for color, weather & moisture protection, tested, via NFPA 286 full scale testing

* ANSI 51 testing for incidental food contact

* Passed CAL 1350 - qualify DC 315 as a low-emitting material in the Collaborative for High Performance Schools rating system (CHPS Designed & CHPS Verified)

* Passed strict EPA – V.O.C. and AQMD air emission requirements (for all 50 states)

* 3rd Party tested “Single Coat Coverage” up to 24 Mils WFT, on ceilings and walls, reducing labor costs equaling higher profits

* Meets Life Safety Code 101

* Meets LEED’s point requirements

* No formaldehyde

 

Characteristics

* Finish: Flat

* Color: White, Ice Gray and Dark Grey are special order

* V.O.C.: (47 g/l)

* Volume Solids: 67%

* Drying Time: @ 77°F & 50% RH To touch 1-2 hours to recoat 2 to 4 hours

* Type of Cure: Coalescence

* Flash Point: None

* Reducer/Cleaner: Water

* Shelf Life: 1 year (unopened)

* Packaging: 5 gallon container

* Shipping weight: 5 gallon pail - 58 lbs.

* Application: Brush, roller, conventional and airless spray


Testing and Certification

* ASTM E84 - Flame Spread 0 Smoke 10

* CAN/ULC S102 FSR 23 SDC 145 - (tested as a system over SPF)

* UL 1715, NFPA 286 - over 140 test passed

* CAN/ULC S 101 - 25 minutes as a system over SPF

* WH Listed - Spec ID 32890

 